Hi Alessandro,
You are right, this is a recent change.
You have some advice in the release notes (actually dating a while ago):
"The best choice, and the recommended setup, is to link rQMD and
Dpmjet-3, and set:
PHYSICS 1.0 0.005 0.15 2.0 3.0 3.0IONSPLIT
"
-M
________________________________
From: owner-fluka-discuss_at_mi.infn.it <owner-fluka-discuss_at_mi.infn.it> on behalf of Alessandro Calamida <alex.calamida2_at_tiscalinet.it>
Sent: Tuesday, May 12, 2020 8:06 AM
To: fluka-discuss_at_fluka.org <fluka-discuss_at_fluka.org>
Subject: [fluka-discuss]: More errors in the new fluka version
Dear FLUKA experts,
I have encounter this error in one of my fluka run: Coalescence
activated and beam above BME limit with no rQMD
and no or incompatible IONSPLIT option!
Execution terminated.
With the old version I compile with ldqmpmp the flukadmpme excutable and
then it run fine. This thing is changed too in the new version?
Best regards and thank you for your time, Alessandro Calamida.
--