[fluka-discuss]: RE:[EXT] RE:Dose from Activity Units

From: Ricardo Manuel Dos Santos Augusto <r.s.augusto_at_cern.ch>
Date: Sat, 30 May 2020 20:36:33 +0000

Dear Dirk,

I am not sure how well this applies to your particular case but ICRP 98 "Radiation safety aspects of brachytherapy for prostate cancer using permanently implanted sources" seems to consider a 0.5 U seed source equivalent to 14.6 MBq of apparent Activity.

Hope it helps,
Ricardo


//Ricardo dos Santos Augusto
TRIUMF-EH&S
Office: +1 604 222 10 47 (6375)
4004 Wesbrook Mall,
Vancouver, BC V6T 2A3, Canada//
________________________________________
De : Bartkoski,Dirk Alan [DABartkoski_at_mdanderson.org]
Envoyé : samedi 30 mai 2020 20:33
À : Ricardo Manuel Dos Santos Augusto
Cc : fluka-discuss_at_fluka.org
Objet : Re: [EXT] RE:Dose from Activity Units

Thank you for the response. It is very helpful. Upon further investigation, you are correct, it is indeed 0.5 U as uGy m^2/h, not amu.

However, now I am unsure how to convert my FLUKA output from Gy/decay to Gy/s based on the source strength. Any direction would be greatly appreciated.

In regard to semi-analogue mode for single chain decay, thanks forever pointing this out. This is my foray into radioactive source implementation and I had not considered the use of TIME-CUT.

_______________________________________________________________________________
Dirk A. Bartkoski, Ph.D.
Computational Scientist | Division of Radiation Oncology
T. Boone Pickens Tower (FCT8.5007)
1515 Holcombe Blvd.
Unit 1420
Houston, TX 77030
(713)794-5026<tel:(713)794-5026>

On May 30, 2020, at 3:07 AM, Ricardo Manuel Dos Santos Augusto <r.s.augusto_at_cern.ch> wrote:


WARNING: This email originated from outside of MD Anderson. Please validate the sender's email address before clicking on links or attachments as they may not be safe.


Dear Dirk,

The approach is correct*, but are you sure about the 0.5 u? in some cases U is used to indicate the source strength.

*Note that your conversion to dose, in your particular case, is valid because you have a single isotope in the chain. Since semi-analogue mode you get all the decay products if you had additional isotopes in the decay chain (e.g. a very short lived and a long lived for instance) the dose rate calculation would be meaningless. In such cases, it is often preferrable to employ a TIME-CUT to restrict the scoring to the parent isotope (age=0) by discarding the daughters' contribution (age according to their respective half-life).

Kind regards,
Ricardo

//Ricardo dos Santos Augusto
TRIUMF-EH&S
Office: +1 604 222 10 47 (6375)
4004 Wesbrook Mall,
Vancouver, BC V6T 2A3, Canada//
________________________________
De : owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] de la part de Bartkoski,Dirk Alan [DABartkoski_at_mdanderson.org]
Envoyé : mercredi 27 mai 2020 16:53
À : 'fluka-discuss_at_fluka.org'
Objet : [fluka-discuss]: Dose from Activity Units

I just want to verify that I am properly converting the units of my results.

I have a 0.5 u radioactive Iodine 125 source that is defined as an ISOTOPE in the BEAM card.
I am using Semi-Analogue in the RADDECAY card and have applied Semi-Analogue to my USRBINs with DCYSCORE.

I want to measure dose to volume from my radioactive source. I have defined the desired volume using USRBIN for DOSE.

From what I understand, my USRBIN with be in GeV/g/decay since I am scoring DOSE from a radioactive isotope.

I want dose rate.

GeV/g/decay*1.602176462E-7 = Gy/decay

Iodine 125 specific activity = 642E12 Bq/g => 642E12 decay/s/g

To get dose rate in Gy/s => (USRBIN value in GeV/g/decay)* 1.602176462E-7*642E12 decay/s/g*0.5*(flair atomic mass unit to gram conversion constant amugr)

My conversion constant is = 1.602176462E-7*642E12*0.5*amugr => Gy/s

Is my approach correct?


_______________________________________________________________________________
Dirk A. Bartkoski, Ph.D.
Research Scientist | Division of Radiation Oncology
<image001.jpg>
T. Boone Pickens Tower (FCT8.5007)
1515 Holcombe Blvd.
Unit 1420
Houston, TX 77030
(713)794-5026

The information contained in this e-mail message may be privileged, confidential, and/or protected from disclosure. This e-mail message may contain protected health information (PHI); dissemination of PHI should comply with applicable federal and state laws. If you are not the intended recipient, or an authorized representative of the intended recipient, any further review, disclosure, use, dissemination, distribution, or copying of this message or any attachment (or the information contained therein) is strictly prohibited. If you think that you have received this e-mail message in error, please notify the sender by return e-mail and delete all references to it and its contents from your systems.
The information contained in this e-mail message may be privileged, confidential, and/or protected from disclosure. This e-mail message may contain protected health information (PHI); dissemination of PHI should comply with applicable federal and state laws. If you are not the intended recipient, or an authorized representative of the intended recipient, any further review, disclosure, use, dissemination, distribution, or copying of this message or any attachment (or the information contained therein) is strictly prohibited. If you think that you have received this e-mail message in error, please notify the sender by return e-mail and delete all references to it and its contents from your systems.

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Sat May 30 2020 - 22:36:33 CEST

This archive was generated by hypermail 2.3.0 : Sun May 31 2020 - 07:36:10 CEST