[fluka-discuss]: [Fwd: Scoring beta energy deposition and fluence in a photodiode]

From: Pratip Mitra <pratipm_at_barc.gov.in>
Date: Wed, 16 Sep 2020 20:08:03 +0530

Forwarding my earlier query in case it got overlooked.

---------------------------- Original Message ----------------------------
Subject: Scoring beta energy deposition and fluence in a photodiode
From: pratipm_at_barc.gov.in
Date: Mon, September 14, 2020 12:04 pm
To: fluka-discuss_at_fluka.org
--------------------------------------------------------------------------

Dear FLUKA Experts,

I am trying to score the energy deposition and fluence in the active
region of a silicon photodiode for a Ru-106 beta source.

SOURCE:

I have used ISOTOPE as the BEAM, delta(phi) = isotropic, Z = 44 and A =
106 in HI-PROPE, and source.f for geometry of the source.

1 RADDECAY card in Semi-Analogue is used. 3 DCYSCORE cards are used in
Semi-Analogue mode, 1 for USRBIN and 2 for USRBDX.

CUTOFF:

PROD-CUT of 1 keV for electron-positron and gamma is set for all materials
via EMFCUT card. Transport cutoff of same value is set for the active
region of the photodiode via EMFCUT card.

SCORING:

1. 1 DETECT card has been used for active region of the photodiode. This
gives the energy spectrum.

2. 1 USRBIN card has been used for active region of the photodiode with
Part = ENERGY. This gives the mean energy deposition per decay.

3. 2 USRBDX cards have been used with one-way fluence scoring for LinE,
Lin(omega) with Ebins = 1024 and Part = ELECTRON and ENERGY, respectively.

RESULT:

1. In USRBDX with Part = ELECTRON, I get nonzero values in the third
column of the tab.lis file. If I plot this I get the electron fluence vs
energy plot peaking at a different value of energy than that of the energy
spectrum obtained using DETECT. I can't understand why this is happening.

2. In USRBDX with Part = ENERGY, I get only zero values in the third
column of the tab.lis file. Why this is happening although I have used a
DCYSCORE card for this USRBDX?

FURTHER QUERIES:

1. I want to score the beta fluence as well as the secondary electrons
fluence (separately) as functions of energy at all the regions, e.g. after
the emission from the source, after the epoxy layer and after each
subsequent layer. Please suggest how to score these.

2. I have attached the input file, the source.f file, the DETECT output
file, the USRBIN output file, and the 2 USRBDX output files. Please check
them and point out if there is any mistake.

Any help will be highly appreciated.

Thanks in advance

-- 
Pratip Mitra
Scientific Officer
Environmental Monitoring and Assessment Division
Bhabha Atomic Research Centre
Trombay, Mumbai 400085, India
Phone: +91 22 2559 5366
Pratip Mitra
Scientific Officer
Environmental Monitoring and Assessment Division
Bhabha Atomic Research Centre
Trombay, Mumbai 400 085
Phone: 022 2559 5366
Mobile: 8240696605/9969799827









__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Wed Sep 16 2020 - 18:39:50 CEST

This archive was generated by hypermail 2.3.0 : Wed Sep 16 2020 - 18:40:10 CEST