Dear Asish
from your message is unclear whether your geometry corresponds to the one
used for the Ambient dose equivalent definition. Ambient dose equivalent
is defined as the dose per unit fluence at 1 cm depth in the ICRU sphere
for a parallel, larger than the sphere, beam impinging on the sphere
itself.
From your message it seems to me that your geometry is fairly different,
also it is not clear where you score the dose, whether in the full sphere
or what.
If you want to compare with the H*(10) estimator you should reproduce
exactly the geometry, irradiation, and scoring conditions under which
H*(10) is defined.
Alfredo
>
> Dear Fluka Experts,
>
>
> I am trying to score dose inside a 5 cm sphere (detector) for 1 MeV
> photons.
> The source is a cylindrical source of 5 cm radius and 10 cm height.
>
>
> Dose obtained in USERBIN is 0.85 x 10E-06 pGy/primary (by converting
> energy
> to dose).
>
>
> While air ambient dose equivalent obtained using AUXSCORE combined with
> USERBIN is obtained as 41.3 x 10E-06 pSv/primary
>
>
>
> I am unable to figure out this discrepancy obtained using these two cards.
> Please suggest me why this discrepancy obtained. The input and output
> files
> are attached here.
>
>
>
>
>
> Thanks in advance
>
> Ashish
>