Hello
The detect card will give you the spectrum of energy deposited by all
particles in your detector region (just like a real detector: at each
event there will be a new entry in the histogram in the channel
corresponding to the total deposited energy).
The user can also define trigger regions or anti-coincidence regions. In
your case, however, you only have the detector region thus you do not
need to set the energy cut value (what(4))
Hope this helps
Paola
On 8/1/24 11:48, muoio wrote:
> Dear experts, I have activated the detect card,
> as attached.I want to determine counts & energy deposited by neutrons,
> and alpha particles. it's correct?
>
> thanks
> A. Muoio