Difference between ALL-PART linked to USERWEIG and DOSE-EQ?

From: Fernandez-Hernando, JL \(Juan\) <juan.fernandez-hernando_at_stfc.ac.uk>
Date: Tue, 24 Mar 2009 16:46:58 -0000

Dear FLUKA users,
 
I have always used to score the residual equivalent dose rate the USRBIN scoring all particle fluence linked to an IRRPROFI card together with DCYTIMES card and a USERWEIG card. I've notice that in the new version I can score DOSE-EQ. I would think that the results from both USRBIN should be the same but they aren't. What are the differences between them?
 
that would be the code I use:
 
IRRPROFI 2.88D+4 6.67D+16
DCYTIMES 0.0 3600.0 8.64D+04
 
USERWEIG 1.0 0.0

DCYSCORE 1.0 long-0h USRBIN
USRBIN 10.0 ALL-PART -47.0 250.0 2.5 250.0long-0h
USRBIN -250.0 -2.5 -250.0 100.0 1.0 100.0&

DCYSCORE 1.0 redrl-0h USRBIN
USRBIN 10.0 DOSE-EQ -77. 250.0 2.5 250.0redrl-0h
USRBIN -250.0 -2.5 -250.0 100.0 1.0 100.0&
 
And find attached the two plots that came out from them.
 
Cheers,
 
   Luis
 
 
 
 

<http://www.plentyoffish.com/member9322419.htm>

Received on Tue Mar 24 2009 - 22:02:57 CET

This archive was generated by hypermail 2.2.0 : Tue Mar 24 2009 - 22:02:58 CET