RE: error

From: Mario Santana Leitner <Mario.Santana_at_cern.ch>
Date: Sat, 27 Jun 2009 01:16:28 +0200

Hi Andrzej,

your input file had a formatting error, in a LAM-BIAS card you had '0. 5' instead of '0.5'
I attach the modified input

Mario

-----Original Message-----
From: owner-fluka-discuss_at_mi.infn.it on behalf of Andrzej Wojciechowski
Sent: Sat 6/13/2009 12:34 PM
To: Mario Santana Leitner
Cc: fluka-discuss_at_fluka.org
Subject: RE: error
 

Dear Mario
I am sending you (In attachement) the results of calculation and history
the error,
Unfortunately I dont to know what is the error reason yet.
All best
Andrzej
 
Dnia 08-06-2009, pon o godzinie 21:15 +0200, Mario Santana Leitner
pisze:
> Hello Andrzej,
>
> I saw some probable causes for your errors
> 1) you had a '-' sign before the VACUUM material in the PHOTONUC card
> 2) you had a '-' sign in two of your USRYIELD cards. Note that to
> score momentum in usryield you don't use the minus sign (like you
> would do in the BEAM card) but you use ie=2 (which you already did)
> 3) there was a tabulator/spacing issue in your third USRYIELD card
> (second line)
>
> please test the attached file (I am running it myself but it takes
> some time...)
>
> Mario
>
>
> -----Original Message-----
> From: owner-fluka-discuss_at_mi.infn.it on behalf of Andrzej
> Wojciechowski
> Sent: Mon 6/8/2009 11:16 AM
> To: fluka-discuss_at_fluka.org
> Subject: error
>
> Dear FLUKA users and programmers
> Could I ask for a reasons of the error (see attachement)?
> Andrzej
>
>
>