Dear FLUKA experts,
I want to obtain the dose equivalent through the usrbin card. the
setting for usrbin card is,
USRBIN 10.0 240.0 57.0 200.0 200.0 200.0TEDepoit
USRBIN -200.0 -200.0 -200.0 80.0 80.0 80.0&
.
After I obtain the results, I want to converse the unit to
mSv/hour. The accelerator paramters is,
particles of per pulse: 1.6*10^13ppp,
pulse frequency: 1Hz.
The unit for dose equivalent from the manual is pSv/primary. Then I
multiple fluka results by the following factor,
(1.6*10^(13))*3600*10^(-9),
where the 3600 is 3600 seconds, 10^(-9) is the factor conversing the
unit of pSv to mSv.
But the I find the results is very larger than that I could image. What
I done is right? From the tutorial of '7th FLUKA Course, Paris
Sept.29-Oct.3, 2008', I find the unit for dose equivalent is pSv in page
10 instead of pSv/primary. Which is an error?
My input file is in attachment. Thanks very much in advance!
Hantao Jing
2009-8-27
* E:\TailEnd\dump7p5\dumpFe\E.dat
* Created: 27.8.2009
* At: 7:56:51
TITLE
MC-CAD Test
GLOBAL 1000.0 0.0 0.0 0.0 1.0 0.
* ..+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
BEAM -1.6 0.0 0.0 20.0 0.0 -1.0PROTON
BEAMPOS 0.0 0.0 -60.0
GEOBEGIN
0 0 MC-CAD
* BH1
RPP BH1 -5000.00 5000.00 -5000.00 5000.00 -5000.00 5000.00
* Incore
RCC Incore 0.00 0.00 -250.00 0.00 0.00 500.00
300.00
* VA1
RPP VA1 -2500.00 2500.00 -2500.00 2500.00 -2500.00 2500.00
END
* Reg # 1
* BH; assigned material: Blackhole; mat # (1)
BH 5 +BH1 -VA1
* Reg # 2
* VA; assigned material: Vacuum; mat # (2)
VA 5 +VA1 -Incore
* Reg # 3
* Incore; assigned material: Aluminium; mat # (10)
Incore 5 +Incore
END
GEOEND
ASSIGNMAT 1.0 1
ASSIGNMAT 2.0 2
ASSIGNMAT 10.0 3
*
* ..+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
USRBIN 10.0 240.0 57.0 200.0 200.0 200.0TEDepoit
USRBIN -200.0 -200.0 -200.0 80.0 80.0 80.0&
AUXSCORE USRBIN TEDepoit TEDepoit 1.0AMB74
* ..+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
RANDOMIZ 1.0
* ..+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
START 10000.0
*USROCALL
STOP
Received on Fri Aug 28 2009 - 10:21:04 CEST
This archive was generated by hypermail 2.2.0 : Fri Aug 28 2009 - 10:21:34 CEST