Re: X-Ray Fluorescence

From: Stefan Roesler <sroesler_at_mail.cern.ch>
Date: Sun, 21 Mar 2010 22:08:09 +0100

Hi Nicholas

In general, fluodt.dat is not available in ASCII format to the user. For
exceptions please contact directly Alfredo Ferrari.

Best regards
Stefan

On Tue, 16 Mar 2010, Nicholas Bolibruch wrote:

> Dear Masters of Fluka,
>
> I am running simulations of X-ray region interactions (8 keV to 30 keV) using
> Fluka for the synchrotron I have an internship with and have had some good
> results so far. I've been comparing results from Fluka to NIST and the X-Ray
> Data Booklet tables, and the comparison has been quite good - consistently
> 41-43 eV differences for copper X-ray transitions, the gold results are not as
> consistent - but are in some cases more accurate. I am trying to understand
> why I do have one transition with an intensity almost double of what is shown
> in the tables.
>
> So for these reasons, I'm exploring Fluka's handling of fluorescence, and
> noticed that Fluodt.dat is a binary file. Is there an ASCII copy available of
> Fluodt.dat anywhere? --Nicholas Bolibruch
>
>

-- 
___________________________________
Stefan Roesler
CERN, DGS-RP
CH-1211 Geneva 23
Switzerland
Phone:  +41-22-7679891
Fax:    +41-22-7669639
E-mail: Stefan.Roesler_at_cern.ch