Re: AMB74 and flair

From: Paola Sala <paola.sala_at_cern.ch>
Date: Tue, 5 Oct 2010 11:56:20 +0200

Dear Hamideh
You have first to define the estimators,
asking for DOSE-EQ as scored quantity. For instance:

USRBIN 11.0 DOSE-EQ -40.0 10.0 15.0 TargDEQ
USRBIN 0.0 -5.0 100.0 200.0 &

Then choose the set of conversion coefficient that you want to use
for the conversion from fluence to dose, using the
AUXSCORE card. As "Type" choose the type of estimator ( here USRBIN),
and as "set" the conversion chosen, as "det" the detector name.
For ambient dose equivalent, the AMB74 set is provided:
AUXSCORE USRBIN TargDEQ TargDEQ AMB74

Please look at the description of the AUXSCORE card in the manual to
have more details and possibilities.
Warning: no conversion is available for heavy ions!

On Tue, 2010-10-05 at 00:01 +0330, Hamideh Jalali wrote:
> Dear FLUKA users
>
> How can I set estimators or detectors in flair
> to score ambient dose equivalent?
>
> Regards
> Hamideh
>
Received on Tue Oct 05 2010 - 16:05:06 CEST

This archive was generated by hypermail 2.2.0 : Tue Oct 05 2010 - 16:05:06 CEST