Re: Fluka-ready Human phantom

From: Alexander Vlasov <Alexander.Vlasov_at_pobox.spbu.ru>
Date: Mon, 13 Dec 2010 16:24:38 +0300 (MSK)

Dear Hemant Kumar Patni

It is really usefull data (seems, necessary dimensions: 256x256x220 for MF,
256x256x174 for AF). I also mentioned recent RPD paper about DCC with FLUKA
of you and your colleagues. I still did not obtain full text and may not
estimate speed of FLUKA for such computations. Could you inform, if it
use necessary optimization for voxels. I am asking because MCNP start
to use lattice speed tallies only at 2004 and only after that DCC for
voxel phantoms may be calculated during few minutes instead of 1-2 days.

Sincerely
Alexander Vlasov
St.-Petersburg, Russia

On Mon, 13 Dec 2010 9:25, patnihk_at_barc.gov.in wrote:
> A segmented CT data for adult male and female reference phantoms are
> published in the joint report of ICRP/ICRU as ICRP publication no. 110.
>
> The link for the supplementary data is as follows:
> http://www.sciencedirect.com/science/MiamiMultiMediaURL/B6T45-4XRHBDG-6/B6T45-4XRHBDG-6-F/4965/html/S0146645309000311/9fa3cc7a4fe3fc27f15d9ad877cb4a10/mmc1.zip
>
>> Dear Fluka users,
>>
>> I am looking for a publically available human phantom or full body CT
>> scan data set for Fluka simulation. Google searches provide too much
>> noise to find anything easily.
>>
>> Thank you for your time,
>>
>> Nicholas Bolibruch
>> Canadian Light Source Inc.
>>
>
>
> Hemant Kumar Patni || Tel.: +91.22.2559.5351
> IDS, HPD, BARC || Fax.: +91.22.2550.5151
> TROMBAY-400085 || Email:patnihk_at_barc.gov.in
> India || hemantpatni_at_gmail.com
>
>
Received on Mon Dec 13 2010 - 17:58:19 CET

This archive was generated by hypermail 2.2.0 : Mon Dec 13 2010 - 17:58:20 CET