Re: hac-tile energy resolution

From: Ertan Arikan <earikan_at_nigde.edu.tr>
Date: Tue, 10 Apr 2012 16:31:39 +0300

Dear Alfredo and Dear Fluka Experts

In my previous mail I have sent hadronic calorimeter related problem.
As Alfredo said we have removed PHYSICS cards (and also LOW-BIAS has removed).
Could you find both my input and my myrfluka.C root files as an attachment
of this mail.
The obtained energy resolution (SigmaE_{rms}/E_{mean})
is equal to 0.2449 which is 2.57 times higher than geant-4 results.

Could you please tell me is there any wrong in my input (or myrfluka)

Thanks in advance,
Best Regards
Ertan

----- Original Message -----
From: Alfredo Ferrari <alfredo.ferrari_at_cern.ch>
Date: Monday, April 9, 2012 7:55 pm
Subject: Re: hac-tile energy resolution
To: Ertan Arikan <earikan_at_nigde.edu.tr>
Cc: fluka-discuss_at_fluka.org

> Dear Ertan
>
> your cards are completely meaningless!! Where did you get from????
>
> Read the manual, don't kill neutrons, don't use leading particle
> biasingin the EM part, put reasonable thresholds for EM
> particles, ,
> follow the release notes for the PHYSICS cards, and then come
> back if you
> don't find the results you expect.
>
> In general for a calorimeter like run all biasing should be off
> of course,
> no particle should be killed etc etc. Putting cards at random
> will never
> give you a meaningful result.
>
>                         Alfredo
>
> +----------------------------------------------------------------
> ------+
> |  Alfredo
> Ferrari                ||  Tel.: +41.22.76.76119            |
> |  CERN-
> EN/STI                    ||  Fax.: +41.22.76.69474            |
> |  1211 Geneva
> 23                 ||  e-mail: Alfredo.Ferrari_at_cern.ch  |
> | 
> Switzerland                    ||                                   |
> +----------------------------------------------------------------
> ------+
>
> On Mon, 9 Apr 2012, Ertan Arikan wrote:
>
> > Dear Fluka experts,
> >
> > I study about the hadronic-tile calorimeter=2E Energy
> resolution results
> >  (I have obtained by using fluka (2011 version) ) are 2
> times higher
> > than GEANT4-results
> >
> > Somebody used the fluka-2006 version for the energy resolution of
> > hadronic-tile calorimeter
> >
> > Question
> > 1)  Why the energy resolution results are 2 times higher
> than GEANT4-results
> >
> > 2) Which physics card I should use in fluka-2011-version or
> >  I try to find the fluka-2006 version.
> > How can I find fluka-2006 version?
> >
> > ------- some CARDs in my input-----
> > GLOBAL       
> 10000.      -
> 1.       0.0       0.0        1.
> >
> DEFAULTS                                                                CALORIME
> > BEAM          -
> 200.                                               10.PION-
> >
> PHYSICS           3.     1000.     1000.     1000.     1000.    1000. EVAPORAT
> > PHYSICS       
> 1000.     1000.    
> 1000.     1000.    
> 1000.    1000.PEATHRES
> >
> PHYSICS           2.    1000.     1000.  3-HELIUM  @LASTPAR   1.DECAYS
> > LOW-BIAS        
> 26.      261.      0.85      reg1  @LASTREG        1.
> > EMFCUT        
> 0.001    0.0004     
> 204.      reg1
> @LASTREG       1.
> > -----------------------------------------------------
> >
> > Thanks for your help
> >
> > Ertan Arkan
> >
>
Received on Wed Apr 11 2012 - 10:56:37 CEST