RE: stepsize for neutral particles

From: Anna Ferrari <a.ferrari_at_hzdr.de>
Date: Thu, 12 Apr 2012 17:38:08 +0200

Hallo Brandon,
no, the cards to control the stepsize refer all to charged particles, the
reason being the eventual need to tune the step with respect to the dE/dx
along the track (between them: STEPSIZE sets a minimum and maximum step size
on a region-by-region basis for all charged particles, EMFFIX sets the size
of electron steps corresponding to a fixed fraction of the total energy on
a material basis, FLUKAFIX sets the size of the step of muons and charged
hadrons to a fixed fraction of the kinetic energy in different materials).
Neutral particles are tracked until a new interaction occurs, without energy
loss along the track (Mtrack=3D0 in TRACKR). If you want to make the steps
shorter, you could eventually introduce artificial boundaries: at the boudaries
all the steps are forced to end.

Hope it helps,
regards,

Anna

-----Original Message-----
From: owner-fluka-discuss_at_mi.infn.it [mailto:owner-fluka-discuss_at_mi.infn.it] On Behalf Of REDDELL, BRANDON D. (JSC-EV511)
Sent: Mittwoch, 11. April 2012 18:01
To: fluka-discuss_at_fluka.org
Subject: stepsize for neutral particles

Dear FLUKA team,

Is there a CARD to control the stepsize (or equivalent) of neutral particles
such as neutrons and photons?
Received on Fri Apr 13 2012 - 10:05:03 CEST