Re: Dose at Center of Sphere

From: Vittorio Boccone <boccone_at_cern.ch>
Date: Thu, 5 Jul 2012 23:06:41 +0200

Did you try with radial importance biasing? Are you scoring Dose or
Equivalent Dose?
If you are scoring DOSE and if the dimensions of the detector are very
small in comparison with the Sphere (is it a shielding?) you can also
think about trying to score the dose on a slightly larger region.
Cheers
v.
On 13/06/2012 16:17, REDDELL, BRANDON D. (JSC-EV511) wrote:
> Dear FLUKA users,
>
> Computing dose at the center of sphere of material is time consuming using
> Monte Carlo codes when using an isotropic source routine (such as SFLOOD)
> on a spherical mass where the radius is much larger than the detector radius at the origin.
> Are there any clever methods of solving this problem that significantly reduces the simulation time?
>
> Thanks.
>
Received on Fri Jul 06 2012 - 11:19:01 CEST