Obviously I forgot to attach the file, sorry for the inconvenient
Francesco
Il 30/07/2013 15:32, Francesco Rossetto ha scritto:
> Good evening,
> I encountered some problem using in the same simulation both the card
> DCYSCORE and AUXSCORE. I wanted to know the neutron dose during the
> irradiation time, so I put a USRBIN detector in the input file and a
> AUXSCORE card in order to check if I was able to see neutron dose per
> unit primary weight. The results were confirming that there was a
> non-zero neutron dose. As soon as I tried to put also the DCYSCORE card
> for a negative cooling time (so during the irradiation), the neutron
> dose map was zero all over the space. Where is the problem? Maybe I did
> not put the cards in a correct order, in any case I attach the input
> file
>
> Thank you for the support
>
> Francesco
>
>
- chemical/x-gamess-input attachment: test.inp
Received on Tue Jul 30 2013 - 17:49:22 CEST