Re: [fluka-discuss]: The Use of MULSOPT

From: paola sala <paola.sala_at_cern.ch>
Date: Sat, 28 Dec 2013 16:47:28 +0100

Hello,
yes you are setting single scattering everywhere, and the value in
what(6) does not matter, provided that it is larger than 1000.0
Greetings
Paola
On 12/25/2013 04:04 AM, yyc2011_at_mail.ustc.edu.cn wrote:
> Dear everyone,
>
> In my input file,I want to activate single scattering everywhere so as to deal with my problem.I set the card MULSOPT as follows.
> "MULSOPT 0.0 1. 1. 999999.GLOBAL"
>
> Am I right if I activate single scattering everywhere like this? On the other hand,does it matter if I set what(6)=9999 or 999999 in the MULSOPT card? In other words,will the result differ when I set what(6)=9999 or 999999 in the MULSOPT card?
>
> Best Regards
> Chen Yuan
>
Received on Sat Dec 28 2013 - 18:27:11 CET

This archive was generated by hypermail 2.3.0 : Sat Dec 28 2013 - 18:27:12 CET