[fluka-discuss]: USRBDX

From: Monica Huerta <mhuerta_at_essbilbao.org>
Date: Wed, 17 Sep 2014 12:27:29 +0200

Dear Fluka users,

I have a proton beam impinging on a *stainless steel collimator. I want
to calculate the number of backscattered protons produced and therefore,
I have set a USRBDX card with type I1,LinE,Lin**Ω. **However, **I am
confused about the normalisation **factor since I am not totally sure
about the output units of the calculated current. **Should I assume them
to be Part/GeV/cmq/pr? In addition, what is the difference between
plotting “value Y” and “value <X>*Y”?.*

*I would be very grateful if anyone could help me with th**is**issue. *

*Best regards

*
-- 
Monica Huerta
Researcher at the Applications Group
Ugaldeguren III
Poligono A - 7B
48170 Zamudio (Vizcaya)
Spain
+34 946 076 859
www.essbilbao.org
Received on Wed Sep 17 2014 - 13:56:42 CEST