[fluka-discuss]: Should Coalescence mechanism be activated for calculating photoneutron yield?

From: George Kharashvili <georgek_at_jlab.org>
Date: Tue, 16 Dec 2014 16:34:06 -0500 (EST)

Dear FLUKA experts,

Should coalescence mechanism be activated using PHYSICS card if one is interested in photoneutron yields, but NOT interested in calculating residual activities?

It is clear that for activation calculations both EVAPORATion and COALESCEnce are needed.

Thanks you

--
George Kharashvili
Jefferson Lab Radiation Control
757-269-6435
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Alternatively, just send an email to majordomo_at_fluka.org with the following single line as the body of the email:
unsubscribe fluka-discuss
Important recommendation: the email has to be sent from the *same* email address used for the registration, in particular one should *not* use an alias for this email address.
Received on Tue Dec 16 2014 - 23:58:21 CET

This archive was generated by hypermail 2.3.0 : Tue Dec 16 2014 - 23:58:22 CET