[fluka-discuss]: Absorbed Dose to water from neutrons - separate scoring of absorbed dose from recoil protons and neutron capture gammas?

From: Felix Ernst Horst <felix.ernst.horst_at_kmub.thm.de>
Date: Fri, 13 Feb 2015 11:50:22 +0100

Dear FLUKA experts,

I am currently simulating the absorbed dose profile from neutrons
(spectrum from ~10 MeV down to thermal energies) in a water phantom by
USRBIN.
That dose distribution should consist of amounts from recoil nuclei (in
water mainly recoil protons) and gamma photons from neutron capture (in
water mainly on hydrogen) respectively their secondary electrons. Is it
possible to separate these two dose components from each other (e.g. by
switching off one of these two interaction mechanisms while the other
remains switched on)?
Which physic cards are responsible for these two mechanisms?

Thank you
Regards

Felix

-- 
Felix Horst, B.Sc.
Institut für Medizinische Physik und Strahlenschutz (IMPS)
Technische Hochschule Mittelhessen
Wiesenstr. 14, 35390 Gießen
Raum D10.12a
Telefon: 0641 309 2642
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Feb 13 2015 - 13:27:37 CET

This archive was generated by hypermail 2.3.0 : Fri Feb 13 2015 - 13:27:40 CET