Re: [fluka-discuss]: Dose-equivalence and Dose-rate

From: NKANYISO ROBERT Mantengu <3477531_at_myuwc.ac.za>
Date: Thu, 16 Apr 2015 14:49:37 +0200

Hi Vasilis,

I don't know if I've got you correctly, do you mean say that I have to use
RADDECAY, IRRPROFI, DCYTIMES cards so that I will be able to declare the
beam intensity as well as cooling times?

Regards,
N.R Mantengu

On Thu, Apr 16, 2015 at 2:35 PM, Vasilis Vlachoudis <
Vasilis.Vlachoudis_at_cern.ch> wrote:

> Hi,
>
> on the prompt run as you are performing FLUKA will output from your USRBIN
> pSv/primary
> which is a simple conversion to Sv/(unit time) = pSv/primary / 1e12
> (pSv->Sv) * I
> where I your beam intensity protons/second
>
> regards
> Vasilis
>
> ------------------------------
> *From:* owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it]
> on behalf of NKANYISO ROBERT Mantengu [3477531_at_myuwc.ac.za]
> *Sent:* 15 April 2015 17:50
> *To:* fluka-discuss_at_fluka.org
> *Subject:* [fluka-discuss]: Dose-equivalence and Dose-rate
>
> Dear FLUKA users,
>
> I'm trying to score the dose rate to see that how many Sv/(unit time),
> but my data that I get out of the run doesn't give me that information.
>
> Any help will be appreciated.
>
> NB: I have also attached the input file.
>
> Regards,
> N.R Mantengu.
>


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Apr 16 2015 - 16:10:59 CEST

This archive was generated by hypermail 2.3.0 : Thu Apr 16 2015 - 16:11:00 CEST