Re: [fluka-discuss]: Dose calculation (Unit: Gy/min)

From: Amit Kumar <amit.live.sal_at_gmail.com>
Date: Thu, 4 Jun 2015 11:37:27 +0530

Dear HoSeung, Santana

Since there is always some error in the calculated quantities (dose).
Therefore, if dose has been calculated by simulating 10e5 number of
primaries(electron in this case) and then if we multiply it with 10e15 to
get dose corresponding to 10e15 primaries then error will be simply
multiplied. But if dose has been calculated by simulating 10e15 primaries
then error will be reduced.

That's why I am thinking 10e15 number of primaries should be used in the
simulation. I have not seen how much CPS would be appropriate for this
simulation but I am expecting it to be difficult.

On Thu, Jun 4, 2015 at 10:28 AM, HoSeung Song <genesjp_at_skku.edu> wrote:

>
>
> Dear Santana,
>
>
>
> Thank you for your reply. As I told you, my interest is to simulate dose
> in Gy/min.
>
>
> The target is now fixed yet. It should be a certain object such as
> bag, box, and etc. But for now lets say the absorbed dose in air. How can I
> calculate absorbed in Gy/min.
>
>
> If I simulate a 10E15-16 primary particle number, it seems that simulation
> time will be so large, is there some way to simulate such kind of large
> primary numbers?
>
>
> What if I reduce a number of primaries and do the same simulation. can we
> believe those results?
>
>
> Thank you and sorry for your incovenience.
>
>
> Regards,
>
> Ho-seung Song
>
>
>
>
>
> On Wed, Jun 3, 2015 at 10:16 PM, Santana, Mario <
> msantana_at_slac.stanford.edu> wrote:
>
>> Hi HoSeung,
>>
>> Results are normalized per primary (in your case per incident
>> electron).
>>
>> Thus, to normalize your results per minute you need to multiply those
>> by 7.5E12 x 250 * 60:
>>
>> Results 7.5E12 e 250 pulse 60 s
>> ----------- x --------------- x --------------- x -----------
>> e pulse s min
>>
>> Please note that Gy is the unit for absorbed dose density [J/kg], so
>> you should score it in your target of interest, not in air (unless you want
>> to know the absorbed dose in air).
>>
>>
>>
>> From: HoSeung Song < genesjp_at_skku.edu>
>> Date: Wednesday, June 3, 2015 7:26 AM
>> To: fluka-discuss < fluka-discuss_at_fluka.org>
>> Subject: [fluka-discuss]: Dose calculation (Unit: Gy/min)
>>
>>
>>
>> Dear Fluka users,
>>
>>
>> I am conducting a simulation with 15 MeV electron beam to tunsgen target
>> to generate photon and neutron. After the target, I put conical shape
>> collimator to focus the photon. I want to calculate a photon dose (Gy/min)
>> at the certain distance from the target (example: 1m, 2m, 3m and etc.).
>>
>>
>> 1. For a input card, I used USRBIN (dose-eq), AUXSCORE (photon) to score
>> the photon equivalent dose, and the unit is pSv/primary. Is this true?
>>
>> The specification of the accelerator is as follows;
>>
>> - number of electrons per pulse: 7.5*10^12
>> - pulse frequency: 250Hz
>> - pulse duration: 6us
>>
>> With these parameters, I want to calculate a photon-dose (Gy/min) with
>> FLUKA. I am a beginner of this program and this field. Can you tell me how
>> to calculate Gy/min at certain point (or surface) with a little bit detail?
>>
>> Thank you in advance.
>>
>> Regards,
>> Ho-seung SONG
>>
>>
>>
>>
>>
>
>
>
> --
> Amit Kumar
> Scientist
> Bhaha Atomic Research Centre
> Mumbai
>
> Phone No. : 022-25592841
> Mobile Number: 9969799819
> Alt. Email Id. amitkumar_at_barc.gov.in
>
>


-- 
Amit Kumar
Scientist
Bhaha Atomic Research Centre
Mumbai
Phone No. : 022-25592841
Mobile Number: 9969799819