Re: [fluka-discuss]: Aluminium x ray transmission

From: Fasso, Alberto <fasso_at_slac.stanford.edu>
Date: Tue, 4 Aug 2015 14:29:18 +0000

I have written already many times and I would like all users to understand that:

A CALCULATION RESULT WITHOUT ITS STATISTICAL ERROR IS MEANINGLESS!!!!!

We will not answer questions expressed without specifying errors.


Alberto

________________________________
From: owner-fluka-discuss_at_mi.infn.it <owner-fluka-discuss_at_mi.infn.it> on behalf of sanjay andola <andolas.007_at_gmail.com>
Sent: Tuesday, August 4, 2015 5:36 AM
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Aluminium x ray transmission

Dear FLUKA experts,
I want to simulate the simple transmission of x-ray through different thickness aluminium plates. in which USRTRK scoring i have used. the results which I am getting from this is 1.6764028E-03 p/cmq/pr at 80 cm distance from the source. 10 mm aluminium is placed in front of detector volume. I am sending the input file also. why it is so different from actual ones. which could be 1.24e-05 p/cm2/pr analyticaly. please elucidate me.

--
Sanjay Andola
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Aug 04 2015 - 18:00:04 CEST

This archive was generated by hypermail 2.3.0 : Tue Aug 04 2015 - 18:00:08 CEST