Dear Marilia
There is an example in FLUKA documentation about dose calculation produced
by gas bremsstrahlung which can help you to solve your problem.
http://www.fluka.org/fluka.php?id=examples&sub=example2
Good Luck
Hamideh
>
>
> On 13 Aug 2015, at 16:45, MARILIA LISBOA DE OLIVEIRA <
> marilia.lisboa_at_cnpem.br> wrote:
>
> Dear Fluka experts,
>
> I am verifying the dose equivalent rates from gas bremsstrahlung (GB)
> outside an optical hutch (3 GeV electron synchrotron machine). This GB is
> produced by the interaction of the primary particle with residual gas (H2,
> CO, CO2 and CH4 molecules) inside a copper chamber at 1E-9 mbar.
>
> I would like to kill the primary electron beam after a 3.2 T dipole and
> all particles produced after it to avoid their dose contribution. I read
> the manual and I am not sure about the best manner to do this (using
> EMF-CUT or the subroutine USRMED or other manner).
>
> Could someone help me in this question please?
>
> Thank you.
>
> With the best regards,
>
> *MarĂlia Lisboa Roca Santo*
>
>
>
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Aug 14 2015 - 20:54:51 CEST