Re: [fluka-discuss]: 10MeV linac

From: Stefan Roesler <sroesler_at_mail.cern.ch>
Date: Thu, 10 Sep 2015 22:53:21 +0200

Dear Masoomeh

Please use What(1)=12.

0.0 <= WHAT(1) <= 8.0 is not allowed for DOSE-EQ, see Note in the manual

                 Not Allowed:
                  - WHAT(2) = 236 (SI1MEVNE), 237 (HADGT20M), 240 (DOSE-EQ),
                    249 (HEHAD-EQ), 250 (THNEU-EQ)

Cheers
Stefan


On Thu, 10 Sep 2015, Masoomeh Yarmohammadi wrote:

> Dear FLUKA experts,
>
> I am studying the shielding design for a 10MeV electron accelerator.
>
> While I run the attached file, the program crashes. The err file say "*** Si 1
> MeV n eq. or hadrons > 20 MeV binnings must be track-length!!!"
>
> I a quite new fluka user. Please let me know the reason of this error and the way for resolving. I should mention by disabling the USRBIN card, the run goes well. While I need to this card and can't disable it.
>
> The inp and err extension file is attached.
>
> Thank you in advance
>
> Masoomeh Yarmohammadi Satri
> Post-Doctoral Research Fellow, School of Particles and Accelerator, Institute for Research in Fundamental Sciences (IPM)
> E-mail : myarmohammadi_at_ipm.ir
>
>

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Sep 11 2015 - 00:30:24 CEST

This archive was generated by hypermail 2.3.0 : Fri Sep 11 2015 - 00:30:27 CEST