Hi
What I would do for such a problem is to calcule the dose rate in uSv/h. To do so use the pSv/primary (from the fluka results) times the beam intensity in particles per second times 3600 divided by 1e6 to go from pSv/s to uSv/h. You can consider a worker is exposed 2000 h/year to estimate the annual dose. I have no experience wit low energy e-accelerator so no feeling of what is required as shielding.
Greetings
joachim
___________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Masoomeh Yarmohammadi [myarmohammadi_at_ipm.ir]
Sent: 17 October 2015 17:10
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Re: PhotoNuc card

Dear Jochim,

Thank you for your help. Could you please help me about the last part of my question that I am in doubt?

Masoomeh Yarmohammadi Satri


----- Original Message -----
From: "Masoomeh Yarmohammadi" <myarmohammadi_at_ipm.ir>
To: fluka-discuss_at_fluka.org
Sent: Thursday, October 15, 2015 8:09:29 PM
Subject: PhotoNuc card

Dear expertise,

In the following of my questions in this community about the shielding design for a 10MeV electron linac.

I ran the simulation just with photonuc card for 7 and 10MeV electron energy. The run with the usebin card, part: Dose Eq and Auxscore, type: neutron didn't receive any dose.

Since I am a quite new person in the shielding/radio-protection field and use of Fluka, could you please help me. If I need to add the LAMbis card for this low energy electron to detect neutrons? how do I adjust this card for this energy?

Also, the received dose for the other Usrbin card with Auxscore part: all type is not high for 70cm concrete beyond the front wall of the target? Since the beam current is 12 micro Amps, I multiply the dose eq (pSV/primary) with 5.4e11 to convert the pSV/primary to mSV/year. Then for the 70cm concert wall (front wall in the attached file) the dose EQ is 10000 mSV/year, much higher than 1mSV/year, the standard value.

Do am I making a mistake in run, design, normalization factor (5.4e111) or the 70cm for 12uA of 7MeV electron beam for copper target is expected?

The inp and fair extension files are been attached

Many many thanks in advance,


Masoomeh Yarmohammadi Satri
Post-Doctoral Research Fellow, School of Particles and Accelerator, Institute for Research in Fundamental Sciences (IPM)
E-mail : myarmohammadi_at_ipm.ir


----------------------------
>
> Dear Expertise
> I am designing a shield for a 10MeV electron linac that will hit a copper,
> W or Aluminum target. Do I need to active the neutron production card that
> is under Physics tab (photoneu)?
>
> Many thanks in advance
>
> Masoomeh Yarmohammadi Satri
> Post-Doctoral Research Fellow, School of Particles and Accelerator,
> Institute for Research in Fundamental Sciences (IPM)
> E-mail : myarmohammadi_at_ipm.ir
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
>
>


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id¬c_info
Received on Sun Oct 18 2015 - 08:53:16 CEST

This archive was generated by hypermail 2.3.0 : Sun Oct 18 2015 - 08:53:17 CEST