Re: [fluka-discuss]: FW: FLUKA

From: James Wetzel <jwwetzel_at_icloud.com>
Date: Wed, 24 Aug 2016 11:24:04 -0500

Ok just as a follow up I created the same plot, but I used 10 cycles, with START = 500,000.

I’m not sure what this does, but it did seem to make the plot better:


> On Aug 23, 2016, at 10:52 PM, James Wetzel <jwwetzel_at_icloud.com> wrote:
>
> Hi Joachim,
>
> Ok I was getting very good, and now I am getting confused again :)
>
> I am really enjoying the FLAIR interface, in particular the ability to save the plots in a workspace.
>
> I made this beautiful plot (attached), of the normalized dose over 67 hours of irradiation: a USRBIN XYZ DOSE with 150 bins in X and Y, and 10 bins in Z.
>
> Question one: I’m wondering if this plot looks fine, and if I can normalize this plot in this way and have it make sense. [Is this plotting the average data of all the runs?]
>
> Question two: I ran my input file with No = 150, and combined all the files. In the REGION DOSE USRBIN output file (.lis) I am getting a percentage error of 5% (5.21E+00). However, when I try to manually histogram the energies of the target in the summary tables for all runs, they are all over the place! and many of them have 0.0 energy deposited in the target! There is no clear peak, and the values vary widely, from 0 up to 100kGy, pretty evenly. Is this simply a problem of statistics? (N=150?) and if so, how am I getting 5% percent error? And what is the best way to correct this?
>
> Question three: When I try to plot the USRBIN REGION DOSE, the rectangle representing the dose is much larger than the geometry it is alleged to represent, and it is offset quite a bit. I am not sure if this is a problem with the geometry plot, or the region I’ve defined, or the way I’m plotting it. If this is an obvious or common problem, let me know otherwise I will keep tinkering :)
>
> Again and again, thank you very very much-
>
> All my best-
>
> James
>
>
> <CS173.inp>
> <CS173.flair>
>
> <TotalAverageDosePerBin.pdf>
>
>
>> On Aug 22, 2016, at 10:37 AM, Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>> wrote:
>>
>> Hi James
>>
>> The summary table in the output file indicates energy in GeV. The same value can be obtained by using ENERGY in a region based USRBIN. The difference between ENERGY (in GeV) and DOSE is that dose is per mass unit. If you did not specify the volume in the region definition then the difference should be the density of the material (thus if PMMA in your case it should be 1.19). If you see more, maybe send me your input file and I could have a look.
>>
>> Otherwise CsCl can easily be defined as a compound material with the right density and using the COMPOUND card and the atom relative content of 1 / 1. To reproduce your setup this region should exactly overlap with the dimension of your source.
>>
>> Greetings
>> Joachim
>>
>>
>> From: James Wetzel [mailto:jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>]
>> Sent: 19 August 2016 06:53
>> To: Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>>
>> Cc: fluka-discuss_at_fluka.org <mailto:fluka-discuss_at_fluka.org>
>> Subject: Re: [fluka-discuss]: FW: FLUKA
>>
>> And another question that goes with my last email -
>>
>> Could you please explain the difference between the total energy for the region as stated in the table after ‘feeder’ in the .out file, vs. the dose in the USRBIN with the DOSE card selected, using the DCYSCORE card for the same region?
>>
>> I am getting ~2e-7 in the former and ~1e-7 in the latter, and by reading through the manuals I think it is simply a unit conversion of some kind, but I’m not confident in my understanding as of yet.
>>
>> All the best-
>>
>> James
>>
>>
>> On Aug 18, 2016, at 4:02 PM, James Wetzel <jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>> wrote:
>>
>> Hi Joachim,
>>
>> I am really cooking with gas now, all thanks to your help.
>>
>> The cesium source is encapsulated inside rings of aluminum and stainless steel, and the scintillator is resting on an acrylic table.
>>
>> I added all of those geometries, regions, and materials to my input card and the FLUKA dose results are within 10% of experimental measurements at the actual apparatus!!
>>
>> I think I can do even better if I include the right material for the source volume.
>>
>> As it is, I simply put a material with a similar density to cesium chloride.
>>
>> The source is cesium chloride powder filled inside of the aluminum/stainless tin can.
>>
>> How best should I model the activated cesium chloride? Do I need to create a custom material?
>>
>> Thank you again-
>>
>> James
>>
>>
>> On Aug 17, 2016, at 2:59 AM, Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>> wrote:
>>
>> Hi James
>> The normalization seems to be correct. Don’t forget to look at statistical errors for the “production” calculations (the statistics on the plots you sent seems poor, which is ok only for testing but not for comparing with data…). You should aim at less than 5 % statistical uncertainty for this type of “simple” setup.
>>
>> Looking at the input you sent earlier, I have noticed that you have no EMFCUT card specified. While the calculation is still correct, it is advised to explicitly use EMFCUT to set the photon/e-/e+ transport and production thresholds (especially in your case as you have a pure em calculations)…
>>
>> Concerning the description of your setup I would think that the Cs-137 is in some kind of matrix material (and encapsulated ?). If this is the case you should maybe include it in the geometry (the matrix material should overlay the dimension of the source description) to take self-absorption effects into the calculations.
>>
>> Glad to hear that FLUKA was helpful for your application.
>>
>> Cheers
>> Joachim
>>
>>
>>
>> From: James Wetzel [mailto:jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>]
>> Sent: 16 August 2016 00:45
>> To: Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>>
>> Cc: fluka-discuss_at_fluka.org <mailto:fluka-discuss_at_fluka.org>
>> Subject: Re: [fluka-discuss]: FW: FLUKA
>>
>> Hi Joachim,
>>
>> I think I have done it! Endless thank yous for your help. This is a very important result for us.
>>
>> I have attached slides which show my results and my calculations / conversions.
>>
>> If possible, would you please review them for accuracy to make sure I understand exactly the FLUKA output?
>>
>> Thank you again, this is very awesome software and I am glad to be able to use it now.
>>
>> Best-
>>
>> James
>>
>>
>>
>> On Aug 15, 2016, at 3:14 AM, Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>> wrote:
>>
>> Hi James
>>
>> To the questions in your slide, “Shouldn’t Source be 0 to 30 cm?”
>>
>> What you are defining is the height of two cylinders. One with 30 cm (external boundary) and one with 0 cm (internal boundary). Thus your source is a cylinder centred on zero and extending on a height of 30 cm (from -15 cm to 15 cm). You can add a second BEAMPOS card to specify the centre of the cylinder (shift it by 15 cm) to have the source extending from 0 – 30 cm.
>>
>> See slide 8 fpr the cylindrical shell source description.
>> https://indico.cern.ch/event/334606/contributions/779788/attachments/653364/898409/AdvancedSources2014.pdf <https://indico.cern.ch/event/334606/contributions/779788/attachments/653364/898409/AdvancedSources2014.pdf>
>>
>>
>> 1 - What are the units on the cb axis for “photon”?
>>
>> As you are scoring photon fluence, it is photon/cm2 for one Cs-137 isotope decay. (note that it is a 2 D projection averaged over all the z bins). You could multiply by the source activity to have photons/cm2/s.
>>
>> 2 - What are the units on the cb axis for “dose”?
>>
>> For dose (energy deposited per unit of mass) the unit in FLUKA is expressed in GeV/g (and again this is the average deposited energy for a single decay). You can convert it to Gray (J/kg) and multiply again per the activity to compare with your setup.
>>
>> 3 - How do I calculate the total dose absorbed by the target?
>>
>> From the existing runs you can have a look at the .out files which have been generated. Look for the summary table for deposited energy (make a query for “All cases handled by Feeder” in the files the table is just after). Then you have for each region the deposited energy. In this case this is GeV/cm3 (but as you are not specifying the volume of the region it is in reality GeV). You need to devide by the weight of material in the region and change the unit to get Gray.
>>
>> Similar result can be obtained by calculating DOSE with a USRBIN per region (instead of Cartesian based). In this case you can use the different post processing utility to average the results and have the estimate of the statistical uncertainty (transform the averaged file to ascii to read the values).
>>
>> Cheers
>> Joachim
>>
>>
>>
>>
>>
>> From: James Wetzel [mailto:jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>]
>> Sent: 15 August 2016 05:08
>> To: Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>>
>> Cc: fluka-discuss_at_fluka.org <mailto:fluka-discuss_at_fluka.org>
>> Subject: Re: [fluka-discuss]: FW: FLUKA
>>
>> Hi Joachim,
>>
>> This has been extremely helpful, and I feel like I am almost there.
>>
>> I tried to figure the following questions out on my own, but couldn’t quite get there.
>>
>> I’ve attached 4 slides as a PDF showing my results, and my main question deals with interpreting them.
>>
>> Namely:
>>
>> 1 - What are the units on the cb axis for “photon”?
>> 2 - What are the units on the cb axis for “dose”?
>> 3 - How do I calculate the total dose absorbed by the target?
>>
>> Thank you very much for all your help so far!!
>>
>> James
>>
>>
>>
>> On Aug 12, 2016, at 2:19 AM, Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>> wrote:
>>
>> Hi
>> You are missing the following cards for the activation of the decay of the “source” isotope (semi-analogue mode)
>>
>> RADDECAY 2.0
>>
>> And to associate the detectors (two USRBIN) to score from decay particles
>>
>>
>> DCYSCORE -1.0 0. 0. doses doses USRBIN
>>
>> DCYSCORE -1.0 0. 0. photon photon USRBIN
>>
>> It should work adding those cards and you should be able to check that it is consistent with the “mono-energetic” photon source
>> Cheers
>> Joachim
>>
>>
>> From: James Wetzel [mailto:jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>]
>> Sent: 11 August 2016 21:33
>> To: Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>>
>> Cc: fluka-discuss_at_fluka.org <mailto:fluka-discuss_at_fluka.org>
>> Subject: Re: [fluka-discuss]: FW: FLUKA
>>
>> Alright many thanks for your help this far -
>>
>> The geometry makes sense and looks good in the viewer without any errors.
>>
>> I was able to get dose values on a map with the extended source of mono energetic photons, however, when trying to set up the isotope, my plots are empty! And I think there are errors, but I’m not seeing any on the output.
>>
>> I’ve attached my updated inp file - I assume I am probably initializing the isotope incorrectly.
>>
>>
>> On Aug 11, 2016, at 1:10 PM, James Wetzel <jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>> wrote:
>>
>> Thank you very much!
>>
>> In this case, the entire radiator is exposed to the scintillator, there is no collimation, which should create a 1/r effect, compared to a 1/r^2 effect, naively, so I think I need to simulate the entire cylinder as being an activated source.
>>
>> Will this still accomplish that?
>>
>>
>>
>> On Aug 11, 2016, at 11:56 AM, Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>> wrote:
>>
>> Hi James
>>
>> Looking at your input a few things.
>>
>> The geometry errors:
>>
>> You define your blakchole external and internal surface with the same sphere radius (use a big number for the blakchole)
>>
>> SPH blkbody 0.0 0.0 0.0 50.0
>> * Air sphere
>> SPH air 0.0 0.0 0.0 50.0
>>
>> To define the blackbody replace :
>>
>> BLKBODY 5 +blkbody -(air+Plastic)
>> By (“Plastic” is already contained inside air…)
>> BLKBODY 5 +blkbody -air
>>
>> The error problem should be solved with the above.
>>
>> For scoring, you can use a region based USRBIN Scoring for DOSE (GeV/g) in the region describing your scintillator.
>>
>> For accuracy of the results, did you consider simulating the collimation system of the irradiator and a point source and isotropic source inside ? I have no experience with irradiator but I am not sure how you can derive from the source activity the photon fluence out of the collimator. I guess that using only solid angle does not work due to scattering effect ?
>>
>> For the source description, note that instead of using mono-energetic 667 keV photon you can use an isotope as the source and benefit from the decay data in FLUKA (of interest for more complicated cases and to get accurate branching ratio which for example is not 100 % for decay of Cs-137 in Ba-137m emitting the 661.6 keV gamma…).
>> To do so look at the course material related to definition of sources slide 21 in the following presentation (don’t forget to activate the decay of the particle by calling the RADDECAY card:
>>
>> https://indico.cern.ch/event/442634/contributions/1096523/attachments/1186817/1721027/18_Activation_2015.pdf <https://indico.cern.ch/event/442634/contributions/1096523/attachments/1186817/1721027/18_Activation_2015.pdf>
>>
>> For normalization, the results (deposited energy) will be by isotope decay so you just need to multiply the results by the source activity ( in Bq)
>>
>> Cheers
>> Joachim
>>
>>
>>
>>
>> From: James Wetzel [mailto:jwwetzel_at_icloud.com <mailto:jwwetzel_at_icloud.com>]
>> Sent: 11 August 2016 17:26
>> To: Joachim Vollaire <joachim.vollaire_at_cern.ch <mailto:joachim.vollaire_at_cern.ch>>
>> Cc: Giuseppe Battistoni <giuseppe.battistoni_at_mi.infn.it <mailto:giuseppe.battistoni_at_mi.infn.it>>; Paola Sala <Paola.Sala_at_cern.ch <mailto:Paola.Sala_at_cern.ch>>
>> Subject: Re: FLUKA
>>
>> Thank you very much!
>>
>> Attached is my .inp file I am working with.
>>
>> I have a cylindrical gamma radiator of cesium 137, with dimensions Diameter: 2.54 cm and Length: 30.48 cm, and 6 Ci activity.
>>
>> I have a sample of plastic scintillator with dimensions 10cm x 10cm x 0.1cm, which is placed a distance 5 cm from the radiator as in the picture below, where the 10x10cm scintillator plane is parallel with the cylinder, and the center of the plastic is aligned with the center of the cylinder, as below:
>>
>> Radiator: ===============
>> ▲
>> 5cm
>> ▼
>> Plastic Scint: ———
>>
>>
>> What I need at the end of the day is the total dose absorbed by the plastic scintillator, in Gy or Mrad.
>>
>> I am getting Geometry errors (I think), and I’m not sure how to get the dose out properly with scoring.
>>
>> Thank you very much for your help!
>>
>>