Re: [fluka-discuss]: Absolute efficiency of HPGe detector

From: Peter Rubovič <peter.rubovic_at_suro.cz>
Date: Thu, 20 Oct 2016 08:41:36 +0200

Hi Pablo,

my guess would be to sum the efficiencies for every channel.

Best regards,
Peter.

Dne 20.10.2016 v 3:00 PABLO CESAR ORTIZ RAMIREZ napsal(a):
> Hello fluka users:
>
> I have been simulating a HPGe detector and I have been using the Detect
> card to obtain the energy spectrum. I have noticed that the obtained
> output file (.lis) give me the response function, i.e. {the number of
> detected photons by chanel}/{the total number of detected photons}. My
> question is: how can I obtain the absolute efficiency using this card?
> or how can I know the number of total detected photons by the detector?
>
> Thanks in advance.
>
> --
> Pablo Ortiz Ramírez
> Master of Science in Physics
> Faculty of Science, University of Chile
>
> Linux User #528950
> Ubuntu User #32991

-- 