Dear Khalid
The fluence is calculated using a track length estimator when calling USRTRACK. The fluence is determined by summing the “tracks”: distance travelled by the particle between interactions and before it exits the region. The sum of tracks (cm) is then divided the volume (cm3) of the region to obtain the fluence (cm-2).
If you divide 5.2241973E-08 by 7.4999…E-03 (volume you must have provided in the USTRACK card) you obtain 6.9655962E-06
Hoping this help
Cheers
Joachim
From: owner-fluka-discuss_at_mi.infn.it [mtailto:owner-fluka-discuss_at_mi.infn.it] On Behalf Of KHALID SINA
Sent: 06 November 2016 02:34
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: USRTRACK
Dear Fluka users,
I used the card USERTRACK it gives me the following result.
and I dont understand the line 14 and 15
"Tot. response (p/cmq/pr) 6.9655962E-06 +/- 2.965142 %
( --> Track l. (cm/pr) 5.2241973E-08 +/- 2.965142 % )
anyone help or explain ?
Thank you for attention.
khalid