Hi Aracell,
your problem is that the default threshold of electrons in precision (written in your output)
Prompt:
Ecut = 6.1100E-01 MeV, Pcut = 3.3333E-02 MeV
is 100keV (Ecut is total energy 6.11 MeV)
so your electrons are stopped before they are even transported.
You should lower your threshold with the EMFCUT both for the transport and production. The lowest possible is 1keV.
Since you are dealing with a thin foil you should also activate the single Coulomb scattering
with the MULSOPT card
Cheers
Vasilis
________________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of Araceli Navarro Fernandez [araceli.navarro.fernandez_at_cern.ch]
Sent: Monday, January 23, 2017 12:05
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Electron Stripping
Hello Fluka experts.
I am new in fluka and I am trying to track the movement of electrons (87 KeV) in a very thin (1um) carbon foil. But the problem I am getting is that apparently all the energy is deposited at the point (0,0,0) even when I know that the range of electrons at this energy is around 60um, What am I doing wrong?
Thank you vary much!
A.
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id¬c_info
Received on Mon Jan 23 2017 - 18:09:44 CET