From: Stefan Roesler (sroesler@mail.cern.ch)
Date: Wed Jul 12 2006 - 09:31:07 CEST
Hi,
The SDUM in DCYSCORE has to be aligned with column 71 while yours starts
in column 72.
please use
DCYSCORE 1.0 0.0 0.0 1.0 1.0 1.0USRBIN
DCYSCORE 2.0 0.0 0.0 2.0 2.0 1.0USRBIN
DCYSCORE 3.0 0.0 0.0 3.0 3.0 1.0USRBIN
DCYSCORE 4.0 0.0 0.0 4.0 4.0 1.0USRBIN
greetings,
Stefan
On Tue, 11 Jul 2006, Guo Wen wrote:
> Dear FLUKA expert:
> I make another test(the input file attached) to request the
> decays,but still get the same results:the data at defferent decay
> times no change.I use a proton source
> irradiating a lead RPP target and use USRBIN to score dose rate in it
> at four decay times after irradiated,I use four same USRBIN cards with
> four output files,the
> data at four decay times are exactly same,I do not know if there is
> another switch controling the decays except the RADDECAY card? I would
> be grateful if you could give me some help.
>
>
>
> My best regards!
>
> guowen
>
-- ___________________________________ Stefan Roesler CERN, SC/RP CH-1211 Geneva 23 Switzerland Phone: +41-22-7679891 Fax: +41-22-7669639 E-mail: Stefan.Roesler@cern.ch