Dear Christopher
I can give advice to use for this purpose mgdraw subroutine, especially
ENDRAW entry. It gives you information about a point where energy was
deposited and you can also receive energy of the particle. You can find
more information there
https://indico.cern.ch/event/489973/contributions/2000440/attachments/1272042/1972478/09_AdvancedUserRoutines2016.pdf
Best regards,
Viktor
2017-06-09 17:31 GMT+03:00 Willis, Christopher <willis.276_at_osu.edu>:
> Hello,
>
> I am relatively new to fluka, and had a question about including a
> detector response function in my binning detectors (USRBIN) using comscw.
> I am simulating a stack of detectors that will be used to measure the
> spatial distribution of a beam of protons at various energies, and want to
> include a dose normalization based on the proton energy at the detector.
> (Essentially, the detector has an under-response for protons whose bragg
> peak lies within the active layer of the detector.)
>
> I've figured out how to get at particle INITIAL energies in comscw, but
> can't figure out how to get the energy at the point of energy deposition
> being binned.
>
> If anyone could offer a suggestion as to how to access this instantaneous
> particle energy, that would be greatly appreciated.
>
> Thanks,
>
> Christopher Willis
>
> Post-Doctoral Researcher
>
> The Ohio State University
>
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Jun 09 2017 - 18:30:47 CEST