Hallo
> 1) I do not need to divide by volume for USRBIN XYZ type to get in pSv per
> primary particle, that is for this case I get the results immediately in pSv
> per primary particles
right (the XYZ elementary volume is known by FLUKA and internally used to
get fluence from tracklength, then dose equivalent is obtained from
fluence through the respective conversion coefficients, which however are
not available for heavy ions like your 7Li beam particles)
> 2)I need to divide by volume for USRBIN REGION type to get in pSv per
> primary particles
right (the region volume is generally unknown to FLUKA and so cannot be
internally used, apart from USRTRACK result normalization purposes if
input by the user in the respective USRTRACK card)
Best regards
Francesco
**************************************************
Francesco Cerutti
CERN-EN/STI
CH-1211 Geneva 23
Switzerland
tel. +41 22 7678962
fax +41 22 7668854
On Sun, 1 Oct 2017, kabytayeva wrote:
> Hello everybody!
> Many thanks for the previous help!I have questions again...
>
> A am interested in equivalent dose in pSv per primary particle. Is it righ
> that:
> 1) I do not need to divide by volume for USRBIN XYZ type to get in pSv per
> primary particle, that is for this case I get the results immediately in pSv
> per primary particles
>
>
> 2)I need to divide by volume for USRBIN REGION type to get in pSv per
> primary particles
>
>
> Many thanks!
>
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Mon Oct 02 2017 - 11:07:47 CEST