Hello Yang,
I suspect there is an error in your geometry. You can try to
activate the geometry debugger, or use Simplegeo as explained
in this message:
http://www.fluka.org/web_archive/earchive/new-fluka-discuss/1758.html
In the meantime, I will have a look at your files.
Best,
Andrea
Il 03/12/2017 14:30, 杨博 ha scritto:
>
> Dear Fluka experts,
>
> I am doing a simulation where the organ dose in a voxel-based human
> phantom is calculated in an Isotropic-emitted photon field.
>
> But when a run starts,an error is encountered and the output file
> shows that " Abort called from FLKAG1 reason 3RD: NRLTGG > 2000 Run
> stopped!".
>
> When i attempted to reduce the simulation particle
> number(e.g.,1E5),the run is good.
>
> I checked the FLUKA Manual and discuss lists but did not find a
> possible explanation.
>
> The input file,output file and other relevant files are attached.Any
> suggestion would be appreciated. Thank you very much!
>
> Best Regards
>
> Yang Bo
>
--
========================================================================
Dr. Andrea Fontana tel: +39 0382 987991
Istituto Nazionale fax: +39 0382 423241
di Fisica Nucleare
Sezione di Pavia e-mail: andrea.fontana_at_pv.infn.it
Via Bassi 6 web : www.pv.infn.it/~fontana
27100 PAVIA, Italy
========================================================================
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info