Dear Riya
> 1. In this case, can I use EM-CASCA card for default precision ?? Will this card be
> able to track both electron and Bremsstrahlung photons produced by the electron beam ??
yes, but set explicitly transport thresholds by EMFCUT
> 2. If I use USRBIN card for the calculation of energy deposition in the target
> volume, will it give energy deposition for electron only or energy deposition for both
> electron and Bremsstrahlung photons ??
both
Best
Francesco
**************************************************
Francesco Cerutti
CERN-EN/STI
CH-1211 Geneva 23
Switzerland
tel. +41 22 7678962
fax +41 22 7668854
On Wed, 21 Mar 2018, riya dey wrote:
>
> Dear FLUKA Experts,
>
> I was trying to calculate dose at a target sphere from a spherical source which has K-40
> uniformly distributed emitting beta radiation. The doubts are the following:
>
> 1. In this case, can I use EM-CASCA card for default precision ?? Will this card be
> able to track both electron and Bremsstrahlung photons produced by the electron beam ??
>
> 2. If I use USRBIN card for the calculation of energy deposition in the target
> volume, will it give energy deposition for electron only or energy deposition for both
> electron and Bremsstrahlung photons ??
>
>
>
>
>
> With regards,
>
> Riya Dey
>
>
>
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Wed Mar 21 2018 - 18:54:12 CET