Dear 李立华,
If I understand your question, I believe you are asking how to calculate
“effective” dose from fluence using USRBDX? If so, I would recommend using
the AUXSCORE card with your USRBDX. There are several sets of
fluence-to-dose conversion coefficients built into FLUKA that you may use.
Note that you also need to specify DOSE-EQ scoring for WHAT(2) of your
USRBDX card.
Below is a link to the AUXSCORE card in the manual.
http://www.fluka.org/fluka.php?id=man_onl
<
http://www.fluka.org/fluka.php?id=man_onl&sub=11> &sub=11
Cheers!
Ted
From: owner-fluka-discuss_at_mi.infn.it [mailto:owner-fluka-discuss_at_mi.infn.it]
On Behalf Of ???
Sent: Monday, November 25, 2019 11:58 AM
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: to get efficient dose
Dear fluka experts:
I want to get efficient dose using conversion coefficient from flux to
efficient dose,the flux can be obtained from usrbdx card,
i also obtained the exact conversion coefficient,how should i do to attach
conversion coefficient with usrbdx card?
best regards
请注意:在您阅读本邮件时,如您了解本邮件内容涉及商业秘密,请您遵守与发信人的商务约定,保守商业机密。如您发现本邮件内容涉及重要商业秘密或与国家秘密相关,请您即刻联系发信人,确认邮件内容是否适于通过互联网传递。
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Mon Nov 25 2019 - 16:44:56 CET