Dear FLUKA experts,
I am extimating the brightens of a water moderator. This is placed in a
experimental setup sourronded by a beryllium reflector except for the
beamline window. The neutrons are produced throught spallation on a
tungsten target with a proton beam of 800 MeV.
I run the simulation with and without a cloating of 650 um for the water
moderator. All the face of it are covered with this coating except for
the one in direction of the beamline.
I supposed that the results of the brightness will change but, instead,
they are the same.
Maybe I missing some cards of physics in the input or I making other
mistakes?
I attach both the input files, the one with the coating is
"fngfluka_ISIS_in_ISIS_Bright_Coup.inp", and the plot of the brillance.
Best regards and thank you for your time, Alessandro Calamida.
--
Questa e-mail è stata controllata per individuare virus con Avast antivirus.
https://www.avast.com/antivirus
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Fri May 08 2020 - 17:32:58 CEST