Hello Mario,
How I link the rWMD and Dpmjet-3? Because I tried to compile using
ldq3mpmp and it said that this feature is not installed.
Best regards and thank you for your time, Alessandro Calamida.
Il 13/05/2020 06:44, Santana, Mario ha scritto:
> Hi Alessandro,
>
> You are right, this is a recent change.
>
> You have some advice in the release notes (actually dating a while ago):
> "The best choice, and the recommended setup, is to link rQMD and
> Dpmjet-3, and set:
> PHYSICS 1.0 0.005 0.15 2.0 3.0 3.0IONSPLIT
> "
> -M
>
> ------------------------------------------------------------------------
> *From:* owner-fluka-discuss_at_mi.infn.it
> <owner-fluka-discuss_at_mi.infn.it> on behalf of Alessandro Calamida
> <alex.calamida2_at_tiscalinet.it>
> *Sent:* Tuesday, May 12, 2020 8:06 AM
> *To:* fluka-discuss_at_fluka.org <fluka-discuss_at_fluka.org>
> *Subject:* [fluka-discuss]: More errors in the new fluka version
> Dear FLUKA experts,
>
> I have encounter this error in one of my fluka run: Coalescence
> activated and beam above BME limit with no rQMD
> and no or incompatible IONSPLIT option!
> Execution terminated.
>
> With the old version I compile with ldqmpmp the flukadmpme excutable and
> then it run fine. This thing is changed too in the new version?
>
> Best regards and thank you for your time, Alessandro Calamida.
>
>
> --
> Questa e-mail č stata controllata per individuare virus con Avast
> antivirus.
> https://www.avast.com/antivirus
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
> <https://www.fluka.org/fluka.php?id=acc_info>
>
--
Questa e-mail č stata controllata per individuare virus con Avast antivirus.
https://www.avast.com/antivirus
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Wed May 13 2020 - 12:59:50 CEST