Hello
I'm sorry , I need some more information about your question. What are you
willing to isolate? If it is dose from decay of activation products,
there are no neutrons. If it is production of radioactive isotopes, the
ones from photons will be very few unless you have a photon or electron
beam.
Regards
Paola
> Dear Fluka experts,
>
> I am running some activation simulation in Fluka, but how to isolate
> gamma activity and neutron activity. Is there any method to do it.
>
> Kindly, help me regarding this issue.
>
> Thanks & Regards
> Ravi Rawat
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
>
>
Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Mon Oct 19 2020 - 12:28:12 CEST