Dear Ertan
Please have a look at Chapter 12} in the Manual. Unlike for other physical
processes, the user has to provide a significant amount of information
via input cards and user routines, e.g. on material properties, light
yield etc. Sub-chapter 12.2.4} also gives an example for scinillation
light.
Furthermore, please see flukapro/(OPPHST) for variables available, e.g.
within mgdraw, including AGOPPH for the age of the photon.
Cheers
Stefan
___________________________________
Stefan Roesler
CERN, DGS-RP
CH-1211 Geneva 23
Switzerland
Phone: +41-22-7679891
Fax: +41-22-7669639
E-mail: Stefan.Roesler_at_cern.ch
On Thu, 23 Aug 2012, Ertan Arikan wrote:
>
> Dear Fluka Experts,
>
>
> I have asked decay time of a plastic scintillator. in addition to decay time I would like to obtain quantum efficiency of plastic
> scintillator
>
> Thanks in advance
>
> Best Regards
>
> Ertan ARIKAN
>
>
>
Received on Fri Aug 24 2012 - 18:26:13 CEST
This archive was generated by hypermail 2.2.0 : Fri Aug 24 2012 - 18:26:25 CEST