Hi I tried to calculate residual dose rate according to this tutorial
but have problems.
http://www.fluka.org/content/course/NEA/lectures/Activation.pdf
I switched on all necessary cards (RADDECCAY, IRRPROFI, DCYTIMES,
DCYSCORE ) and linked USRBIN, RESNUCLEI scoring cards with appropriate
dacay times, and FLUKA runs without errors!
The problem that I get all ZEROS in reporting plots of USERBIN,
RESNUCLEI (in my case type Eq. Dose), and even more for any type of
scored quantity not only Eq. Dose
I also attached my input file if You have time please take a look.
Thanks!