[fluka-discuss]: Re: Abort called from FLLACT
Dear Sunil,
the problem is just that the number of your *negative* cooling times (requiring
a dedicated treatment) times the number of irradiation intervals you input
times the number of generated radioactive chains, exceeds the allocated memory.
The respective vector is already huge, it will be increased by a factor of 3
with new release, but will not get infinite, implying on the user side some
limitation on the product between negative cooling time and irradiation
interval numbers.
Cheers
Francesco
**************************************************
Francesco Cerutti
CERN-EN/STI
CH-1211 Geneva 23
Switzerland
tel. ++41 22 7678962
fax ++41 22 7668854
Received on Fri Apr 11 2014 - 12:32:28 CEST
This archive was generated by hypermail 2.3.0