Dear fluka experts
Recently, I came across a problem in using written source. I wanted to score the activity of the vessel undertaking the irradiation from different particles, like photon, electron and gamma. So I chose the written source.f to achieve my goal, but unfortunately in the progress of executing, it
shown to me the result like that: /usr/local/fluka/flutil/rfluka: line 359: 3621 Aborted (core dumped) "${EXE}" < "$INPN" 2> "$LOGF" > "$LOGF". I don't
to know how to solve this problem, so I attach my input file, input data, and my source.f to ask help from you.
Thank you in advance!
with best regards!
Jianqi Chen
- application/octet-stream attachment: try.dat
- application/octet-stream attachment: source.f
Received on Thu Aug 07 2014 - 14:12:10 CEST