Hi£¬every fluka user£º
Rencently£¬I keep trying to simulate the process of electron with monoenergy of 3MeV hitting Al and PE target with same thickness of 1mm and score the forward photon dose-eq and photon spectrum by USRBDX and AUXSCORE. I found that with the dose conversion factor of EWT74 the dose-eq (1.683E-4 psv/prim) generated by PE target is larger than that (1.179E-4 psv/prim) genrated by Al Target, while with the entry of AMB74 the dose-eq (1.088E-4 psv/prim) generated by Al target is larger than that (4.119E-5 psv/prim) genrated by PE Target and from the photon spectrum, the photon number generated by Al is more than that generated by PE in the all energy range as attached. I checked and rechecked my inputfile and no error was found ,I thick there is a bug existed for EWT74,and hope someone can pay attention to it and help me solve this qusestion because I have to doubt if the previous work using EWT74 is corrected , Thank you so much, the input file and orginal results was attached.
Best regards
Bo yang
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
- application/octet-stream attachment: al.inp
- application/octet-stream attachment: pe.inp
(image/jpeg attachment: al-pe.JPG)
Received on Sat Sep 19 2015 - 14:12:23 CEST