Hello
Use DEFAULT PRECISIOn
MULSOPT to activate single scattering at boundaries
Choose thresholds (EMFCUT ) so that the range is several times smaller
that your layer, keep the same energy threshold in neighboring materials.
As a rue of thumb, minimum size is the one corresponding to the range of
10 keV electrons.
Regards
Paola
> Hello dear FULKA experts!!!.
>
> I want to calculate absorbed dose in thin foil of few micrometers under
> electron beam of 5MeV.
> I would like to know what cards should I use in order to make FLUKA
> calculation more accurate and precise.
> So I need the names of cards with parameters that needs to be activated
> for that.
>
> One more general question:
> Up to what minimum geometry sizes FLUKA can handle calculation precisely?
>
> Any help will be appreciated much!!!
>
> Thank You!
>
> __________________________________________________________________________
> You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
>
Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Sun Jan 31 2016 - 16:35:54 CET