Dear Tao Yang
I have run your inputs on a Laptop running Linux (and not via flupix) and
get
1. the expected BEAMPART fluence
2. a color fluence plot resembling the cascade evolution.
Thus, your observations could be related to you installation.
Cheers
Stefan
On Wed, 22 Jun 2016, YANG Tao wrote:
>
> Hello, everyone!
>
> Recently, I find there are some problems of the new
> version flupix-2011.2c-4_flair-2.2-1. I don't know whether you have the
> problems or not.
>
> 1. The 1 MeV gamma rays were directed towards a simple cuboid lead block.
> USRBDX score card has been used to obtain the transmission values, I/I0,
> where I0 and I are the incident and attenuated photon intensities.
> Theoretically, I0 is 1 photon/primary since the incident photon will all
> penetrate the front surface of the lead block, however, the result (31BIN,
> "rushe") always give ZERO result, it's confusing, where did the photons go?
> and I get the correct result running on the server workstation. The input
> file is gamm.inp
>
> 2. The USBIN results could plot a colorful picture in the old version of
> flupix as shown in figure1, however, the picture can only show the pink
> color shown in figure2 for the same merging files. The input file is blm.inp
>
>
> Could someone help me in these questions please?
>
> Thank you.
>
> With the best regards,
>
>
> Tao Yang
>
> CAS
>
>
>
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Jun 28 2016 - 00:43:45 CEST