Dear Adam,
In principle one can always kill particles in the USRMED routine by setting the particle weight WEE to 0. There are several arguments passed to USRMED, like particle energy and particle type, so one can include some IF statement to kill selectively neutrons above a certain energy. Note that the call to USRMED has to be activated by the MAT-PROP card (WHAT(1) has to be larger than 0.0 and you need to set WHAT(4) to 1.0 and WHAT(5) to _at_LASTMAT if it should be active for all materials). At which energy do you want to set the cut? Beware that below 20 MeV FLUKA uses a group-wise treatment for neutron transport.
Cheers, Anton
________________________________________
From: owner-fluka-discuss_at_mi.infn.it [owner-fluka-discuss_at_mi.infn.it] on behalf of adwasil [adwasil_at_poczta.onet.pl]
Sent: 10 December 2016 21:41
To: fluka-discuss_at_fluka.org
Subject: [fluka-discuss]: Upper limit of neutron energy used in calculations
Dear FLUKA experts.
Is there a possibility to set the cut-off for neutron energy from above? I mean the removal of neutrons above a certain energy from calculations?
Best regards
Adam Wasilewski