From: Thomas Otto (TIS-RP, CERN) (thomas.otto@cern.ch)
Date: Wed Feb 11 2004 - 17:41:44 CET
Dear colleagues,
there are 3 different types of iron available as regards the low-energy
neutron transport properties (LOW-MAT command):
Iron
Iron self-shielded
Iron shield.
Can you explain what the particularities of these different materials
are and in which situations one should use them ?
At the moment I need to estimate shielding for an electron accelerator
with energies above the neutron production threshold.
Thank you,
Thomas Otto
-- Thomas Otto Radiation Protection Group SC-RP CERN CH 1211 Geneve 23 Tel. (+41 22) 76 73272 Fax. (+41 22) 76 79360 thomas.otto@cern.ch
This archive was generated by hypermail 2.1.6 : Wed Feb 11 2004 - 17:51:14 CET