about USRBIN and USRTRACK

From: owner-fluka-discuss@fisica.unimi.it
Date: Wed Feb 25 2004 - 01:23:01 CET

  • Next message: Îäìõ: "About USRTRACK and USRBIN"

    Dear fluka user,
    The attachment is my input file. In my mind, the result got by USRBIN and USRTRACK
    is the same(divided the energy binning). But actually the result is not right. Who
    can help me?
    Thanks a lot
    The result:
    USRTRACK:
       Track n. 1 "photon " , generalized particle n. 7, region n. 4
          detector volume: 1.0000E+00 cm**3
          linear energy binning from 0.0000E+00 to 1.5000E-02 GeV, 1 bins (
    1.5000E-02 GeV wide)
          Data follow in a vector A(ie), format (1(5x,1p,10(1x,e11.4)))
     
           6.6418E+01
    USRBIN
       Cartesian binning n. 1 "photon " , generalized particle n. 7
          X coordinate: from -5.0000E-01 to 5.0000E-01 cm, 1 bins ( 1.0000E+00 cm
    wide)
          Y coordinate: from -5.0000E-01 to 5.0000E-01 cm, 1 bins ( 1.0000E+00 cm
    wide)
          Z coordinate: from 0.0000E+00 to 1.0000E+00 cm, 1 bins ( 1.0000E+00 cm
    wide)
          Data follow in a matrix A(ix,iy,iz), format (1(5x,1p,10(1x,e11.4)))
     
          accurate deposition along the tracks requested
          this is a track-length binning
           9.2276E-02

     
    Zhen Wu
    2004.2.24




  • Next message: Îäìõ: "About USRTRACK and USRBIN"

    This archive was generated by hypermail 2.1.6 : Wed Feb 25 2004 - 09:10:49 CET