Re: FLUKA: BEAMPOS - NEGATIVE argument

From: Alfredo Ferrari (alfredo.ferrari@cern.ch)
Date: Fri Mar 12 2004 - 08:22:29 CET

  • Next message: wuzhen: "About EMF-BIAS"

    Kerry

    the NEGATIVE functionality is working if you DON'T use a source routine,
    if you use a source routine (ie you have a SOURCE data card in the input)
    it is to you to do whatever you like in the source routine. The one
    provided with the code is just an example.

                           Ciao
                          Alfredo

    On Thu, 11 Mar 2004, LEE, KERRY T. (JSC-SR) (UHCL) wrote:

    > Hi,
    >
    > In the newest version of FLUKA, 2003_1, I am making use of the NEGATIVE
    > string in the last argument of BEAMPOS. I have done a run with and without
    > the NEGATIVE string and the results are identical. I them modified source.f
    > such that instead of
    >
    > TZ(LSTACK) = TINZ
    >
    > I replace it with
    >
    > TZ(LSTACK) = -TINZ
    >
    > and this does change the direction of the beam as I expect.
    >
    > Can you verify that the NEGATIVE functionality is not working, or am I doing
    > something wrong?
    >
    > Thanks
    > Kerry
    >
    >

    -- 
    +----------------------------------------------------------------------------+
    |  Alfredo Ferrari                ||  Tel.: +41.22.767.6119                  |
    |  CERN-AB                        ||  Fax.: +41.22.767.7555                  |
    |  1211 Geneva 23                 ||  e-mail: Alfredo.Ferrari@cern.ch        |
    |  Switzerland                    ||          Alfredo.Ferrari@mi.infn.it     |
    +----------------------------------------------------------------------------+
    

  • Next message: wuzhen: "About EMF-BIAS"

    This archive was generated by hypermail 2.1.6 : Fri Mar 12 2004 - 09:03:30 CET