    dear all,

    i have modified some routines to calculate deposited energy (MeV),
    range (um) and LET (MeV/mg/cm2). somehow, i got different ranges,
    which also causes different LET, in silicon when i run the input file
    with the options, NEW-DEFA and PRECISIO. the range value in silicon
    with PRECISIO option is around 3.5 times greater than the one obtained
    with NEW-DEFA option. what could be the reason for this?
    meanwhile, is there a way to call z-coordinates of the medium
    dynamically? i mean, i dont want to recompile mgdraw.f eache time
    after redefining my geometry input file.

    kindly wishes,
    ercan

    ps. in the attached files (*.61) each column corresponds xpos, ypos,
    zpos, ekin, amass of particle for one event.

    =======================